Version 29 (modified by 13 years ago) ( diff ) | ,
---|
tellstick.conf
The file /etc/tellstick.conf
is the file where all devices used by TellStick is configured under Linux. Each device is configured in its own block with the parameter as name/value-pairs:
device { foo = "bar" }
A device has at least four values and another block names parameters
. A typical device can look like this:
device { id = 1 name = "Device 1" protocol = "arctech" model = "codeswitch" parameters { house = "A" unit = "1" } }
- id
- This is a number and must be unique for each device.
- name
- A name for easy identification of the device.
- protocol
- This is the protocol the device uses. More on the different protocols later down.
- model
- The parameter model is only used by some protocols where there exists different types of devices using the same protocol. This can be dimmers versus non-dimmers, codeswitch versus selflearning etc.
- parameters
- This block depends on the protocol specified and is explained under each protocol.
Protocols
arctech
This protocol is used by a lot of devices. Some of them includes:
- Byebye Standby
- Chacon
- CoCo Technologies
- HomeEasy
- Intertechno
- Kappa
- KlikAanKlikUit
- Nexa
- Proove
- Rusta
It has four different models:
- codeswitch
-
This types of devices uses dials on the receiver and remote to address them. The parameter
house
can be A to P and theunit
1 to 16. A typical parameters-block can look like:parameters { house = "A" unit = "1" }
- bell
-
This is bells of the codeswitch type. It only uses
house
and just as modelcodeswitch
it is A to P. Example:parameters { house = "C" }
- selflearning-switch
-
Requires TellStick batch >= 5, TellStick Duo or TellStick Net
The newer ones where the code is learned by the remote/TellStick. Instead of housecodes A to P this is now 1 to 67108863. The unitcode is still 1 to 16. Example:parameters { house = "953934" unit = "1" }
- selflearning-dimmer
-
Requires TellStick batch >= 5, TellStick Duo or TellStick Net
This is the same asselflearning-switch
only these devices supports dimming-commands
brateck
Requires TellStick batch >= 5, TellStick Duo (sending only) or TellStick Net (sending only)
This protocol is used by some projector screens. Example:
- Roxcore
The only parameter used in this protocol is house
. The code is 8 tri-state values soldered into the pcb. The state can be "1", "0" or "-".
A real world example can be found here: http://www.telldus.se/forum/viewtopic.php?t=416
Example:
parameters { house = "101-1011" }
everflourish
Requires TellStick batch >= 5, TellStick Duo or TellStick Net
Added to telldus-core in 2.0.2.
This is the selflearning protocol. For the codeswitch, take a look at
risingsun
.
Brands:
- GAO
The protocol uses house
(0 to 16383) and unit
(1 to 4). Example:
parameters { house = "117" unit = "2" }
fuhaote
Requires TellStick batch >= 5, TellStick Duo or TellStick Net
Added to telldus-core in 2.0.3.
The configuration of these devices is very similar to
sartano
but they are not compatible with each other.
Brands:
- HQ
- Rusta
It uses the parameter code
and consists of ten ones and zeros. Example:
parameters { code = "0010010100" }
hasta
TellStick Duo and TellStick Net can only send, not receive this protocol
Blinds
Uses house
(1 to 65536) and unit
(1 to 15). Example:
parameters { house = "1" unit = "1" }
ikea
These receivers is not sold by Ikea anymore. There is both dimmers and non dimmers. One thing that differs this protocol against all other is that it can control up to ten receivers with just one device.
It uses the parameters system
, units
and fade
:
system
can be 1 to 16.
units
is a comma-separeted list of receivers to address (1 to 10).
fade
is eithertrue
orfalse
and tells a dimmer if is should fade smooth or instand between values.
Example:
parameters { system = "5" units = "2,6" fade = "true" }
risingsun
TellStick Duo and TellStick Net can only send, not receive this protocol
Often small codeswitch receivers. Known brands:
- Conrad (selflearning)
- GAO (codeswitch)
- Kjell & Company (codeswitch)
- Otio (selflearning)
Two models, codeswitch or selflearning:
- codeswitch
-
Uses
house
(1 to 4) andunit
(1 to 4). Example:parameters { house = "1" unit = "1" }
- selflearning-switch
-
Uses
house
(1 to 33554432) andunit
(1 to 16). Example:parameters { house = "5679" unit = "1" }
sartano
This is a very common protocol used by a lot of receivers. It has 10 dip-switches to configure the adress-code. Brands:
- Sartano
- Alpha
- Brennenstuhl
- Elro
It uses the parameter code
and consists of ten ones and zeros. Example:
parameters { code = "0010010100" }
silvanchip
TellStick Duo and TellStick Net can only send, not receive this protocol
Brands:
- Ecosavers
- KingPin - KP100
Two models, ecosavers and kp100
- ecosavers
-
Uses
house
(1 to 1048575) andunit
(1 to 4). Example:parameters { house = "1" unit = "1" }
- kp100
-
Uses
house
(1 to 1048575). Example:parameters { house = "1" }
upm
TellStick Duo and TellStick Net can only send, not receive this protocol
Uses parameters house
(0 to 4095) and code
(1 to 4). Each receiver can only remember one code at a time so using both a normal remote and TellStick is not possible. Example:
parameters { house = "123" unit = "1" }
waveman
Very similar to arctech/codeswitch but the protocol differs just slightly. Brands:
- Waveman
Example:
parameters { house = "A" unit = "1" }
x10
Requires TellStick batch >= 9, TellStick Duo or TellStick Net
This protocol uses the same configuration as arctech/codeswitch. Example:
parameters { house = "A" unit = "1" }
yidong
Added to telldus-core in 2.0.4. Brands:
- Goobay
Uses unit
(1 to 4). Example:
parameters { unit = "1" }